Conversion of a natural gas-fired three-pass smoke tube steam boiler into a steam recovery boiler for heat recovery from the high-purity air volume flow behind an RTO system.
Adaptation of the boiler technology to utilize the exhaust air heat. Integration into the existing process, taking into account an operating pressure of 25.0 bar and an exhaust gas volume flow of 11,000 Nm³/h.
Efficient utilization of the existing heat energy from the exhaust air; reduction in primary energy consumption.
| Steam output | 4.000 kg/h |
| Steam pressure | 25,0 bar |
| Exhaust air volume flow | 11.000 Nm³/h |
| Location | Belgium |
| Services provided by Rothos | Planning, delivery, installation, commissioning |